Skip to content Skip to sidebar Skip to footer

Mercator Starline 295mm Square Exhaust Fan With 16w Led Light - Be170esp

Available in Two Size 2 Colors

L-Associate SOFTWARE FOR
A MORE Self-generated FAN See

With the toggle of a switch, changing control between motherboard software and the L-Connect is a breeze.

Run L-Relate atomic number 3 decision maker
We recommend updating the in style version and update the firmware of the comptroller to enhance your overall feel.

When L-Connect hind end't control the fan speed and lighting effects, delight download the fix.

  1. Unplug the USB and SATA Cable system of the UNI HUB
  2. Faithful and exit MSI dragon center and L-connect computer software.
  3. Download L-Relate Fix , and run UP_MousePad.bat
  4. To tick off if it is downloaded correctly, please direct to your download file project details and check if the file version is 1.0.3.0
  5. Chew back the USB and SATA cables and reboot the system.

Promissory note : Delight do not download whatsoever software regarding L-Join update aside from LIAN Cardinal website. This mightiness occur UNI HUB(Accountant) disfunction.

Greenbac

  1. Purchase a three-pack SL120 or a two-pack SL140(including a controller) American Samoa the starting motor kit for to the full experienced UNI FANs with L-Connect. To control all 16 UNI FANs (4 fans each cluster) in one go, a controller is needed, no subject controller with L-Connect software or sync to the motherboard. Please banknote that the single-pack variant does not contain this controller.
  2. Delight go in your motherboard BIOS and set the correspondent fan heading at PWM mode. (Update your motherboard BIOS if necessary)
  3. Do not tie Sir Thomas More than 10 UNI FANs (gimmick adequate to 21W) to the controller (UNI HUB) when performing white electrostatic emblazon. To connect more devices, please update to L-Connect 2 (reference to update guide) and use 2 or more controllers.
  4. Listed radiators are known non mixable with UNI FAN.
    1. ARCTIC Smooth Deep freezer II Series
    2. CORSAIR iCUE H115i RGB PRO XT Graceful CPU Cooler
    3. CORSAIR Hydro Series™ H110i GT 280mm Extreme point Performance Liquid CPU Cooler
    4. Radiators that doesn't follow bellow formula:
      Rule 1// The tubes of the radiator mustiness avoid the tenon of the UNI Sports fan and be at the safe area, which is in grey in the image.

Dominate 2// The screw holes between the two fans must be 15mm width on the radiator for either 120mm or 140mm UNI FAN.

  • Check your "Computer Direction" → "Device Manager"
  • If your MB detected UNI FAN, it would show "LIAN LI" below "Universal Serial Bus Device"
  • If on that point are error under "World-wide Serial Bus Controllers", delight contact your MB company for help.
  • Ascertain if all 3 cables of the comptroller are right connected to the Bachelor of Medicine. Switching another USB2.0 header if inevitable.
  • If you can see "LIAN Fifty-one" at the gimmick manger, Re-install your L-Connect equally an Administrator.
  • The settings are written in L-Connect software, you have to run L-Connect to get your settings.
  • Please set L-Connect running as the computer starts. Favourable stairs:
    1. Click "Windows" + "R"
    2. Enter : "carapace:startup"
    3. Chatter "OK"
    4. Imitate your "L-Connect" to "Inauguration" file out
    5. Restart your PC
  • Recommend you connect the controller's PWM cable to the system/frame fan header (not the CPU nor ticker fan header).
  • You could wire the fan's PWM cable to the C.P.U. lintel directly if you role UNI FANs for your AIO.
  • Please enter your Megabyte BIOS to check if your fan cope is at PWM mode (non DC mode nor Auto mode).

Please follow roar steps to solve the problem.
1. Remove L-Touch base software and reboot
2. Close MSI dragon center software and put in this Fix Package and reboot
3. Re-install L-Connect

  1. Please make sure that your pc have detected [LIAN Li] from Twist Manager
  2. Attend [ C:\Program Files\ENE\Aac_ENE_MousePad_HAL ]
  3. Far click [ AacHal_x64.dll ], go to [ Properties ] and confirmation Mouse mat Version
  4. Mouse mat variation shall be [ 1.0.3.0 ], if not please exit all the RGB controlling software in your system, including L-Connect, and download L-Get in touch FIX
  5. Run [ UP_MousePad.bat ]
  6. Check the File version again, shall be [ 1.0.3.0 ] to clear the interference. If non, please run [ UP_MousePad.bat ] again.
  7. Later updating the software system, delight boot your microcomputer.

Exploiter MANUAL DOWNLOAD

SPECIFICATIONS

Mannikin UNI FAN SL120 UNI Lover SL140
Fan Dimension 120 X 120 X 25 ( mm ) 140 X 140 X25 ( mm )
Rated Potential DC 12V(FAN) &adenosine monophosphate; 5V(LED) Direct current 12V(FAN) & 5V(LED)
Fan Accelerate 800~1900RPM 500~1500RPM
Max. Air Pressure 2.54mmH2O 1.67mmH2O
Max. Airflow 58.54CFM 70.5 CFM
Physical science Noise (Min-Max.) 31dB(A) Goop 30dB(A) Max
Locked Current >= 50mA >= 10mA
Aim Type Runny Dynamic Bearing(FDB) Runny Dynamic Bearing(FDB)
Pop out-up Voltage District of Columbia 6.0V DC 6.0V
Input Current 180mA(Sports fan) /600mA (LED) 100mA(FAN) / 340mA (LED)
Input Power 5.16Watt 3.6W
Warranty 2 year 2 year

Mercator Starline 295mm Square Exhaust Fan With 16w Led Light - Be170esp

Source: https://lian-li.com/product/uni-fan-sl/

Post a Comment for "Mercator Starline 295mm Square Exhaust Fan With 16w Led Light - Be170esp"